We always keep in mind the convenience of
the disabled and the legal requirements in designing
and manufacturing lifts; mirrors installed to the eye level
of people in wheelchairs, operating panels installed with
in the reach of people in wheelchairs,
and safety bars installed within the carriage.

 
 
 
   

Open space 1.4m X1.4m in front of
elevator opening.

The gap between lobby and hoist way
must be less than 3cm wide.
The effective area for the carriage must
be at least 1.1 m wide by 1.35 m long.
The Effective width for the entrance
must be more than 0.8 m.
The Switches must be located at a height between 0.8m and 1.2 m from the floor.
The control panel must be installed on the
right side when entering the carriage at
about 0.8 m from the floor.
Braille must be provided on the control
panel and on the interphone.
Grab bars must be installed in the carriage
Mirrors must be installed in the back of the carriage (When floor space is 1.4m X 1.4m wide).
Light and audio signals must be installed on every floor of a building to indicate that the elevator is approaching.
Light and audio signals must be installed in the carriage to indicate the floor at which the elevator stops.
While installing the sensor door, make sure that people can be detected within the range of 0.3m to 0.4m from the floor.
 
 
Effective area for the lift
The space needed for a 90 degree revolution
The rear and sides of the wheelchair
1